RA-915AMNG Automatic Mercury Monitor for Natural Gas



Logo Lumex

Reference : RA-915AMNG



RA-915AMNG monitors are designed for continuous mercury measurements in a natural gas stream and are ideal for permanent unattended installation at the gas monitoring stations.

RA-915AMNG monitor for natural gas allows direct rapid analysis of mercury in natural gas, enables prompt reaction to variations of mercury concentrations in the stream, monitoring of the MRU units and other applications.

The RA-915AMNG monitor requires very little maintenance and attention from the plant personnel (service may be done during maintenance shutdown) and requires no reagents/consumables for operation (only filters and lamp require periodic replacement during planned maintenance).

The remote data transfer makes it possible to connect the monitor to data collection systems via RS232, Modbus, and analogue output.



Features & Benefits

  • Direct continuous measurements
  • Low detection limit and wide range of measurement
  • Highest selectivity
  • Long-term calibration stability
  • No chemicals, carrier and zero gases
  • Automatic zero drift and span correction
  • Automatic recalculation to standard conditions
  • Auto control and preventive maintenance functions
  • Robustness and low maintenance
  • Customized configuration



Principle of Operation

Atomic absorption with Zeeman background correction.



Installation

The RA-915AMNG monitors are designed for indoor operation or installation in climate controlled cabinets. The monitors can be installed in standard 19 inch rack.



Equipment & Options

RA-915AMNG Air Mercury Monitor

On request monitors may be equipped with a flow switching device for multiple sampling points



Technical Specifications

 

        Range I        

ng/m3

        Range II        

ng/m3

        Range III        

ng/m3

Measurement Range                    0-2'000 0-150'000 0-3'000'000
Detection limit 1 50 500
Average Interval 5 min Optionnal >2s
Zero drift correction Automatic
Span drift correction Automatic
Sampling gaz condition
Gas pressure Atmospheric (+/-20%)
Flow rate 4-10 l/min 0.5-10 l/min
Gas humidity  Dew point <10°C
Gas temperature  +1°C to +40°C
Concentration of H2S ≤ 50 mg/m3 ≤ 200 mg/m3 ≤ 1'000 mg/m3
Concentration of benzene ≤ 10 mg/m3 ≤ 50 mg/m3 ≤ 2'000 mg/m3
Concentration of mercaptans ≤ 50 mg/m3 ≤ 200 mg/m3 ≤ 1'000 mg/m3
Concentration of aromatic compounds           ≤ 200 mg/m3 ≤ 2'000 mg/m3 ≤ 10'000 mg/m3
Data communication
Communication ports  4-20 mA current loop; 2 USB; RS 232; LAN
Communication protocol Standard: GESYTEC protocol, Modbus
Status output  WORK, SERVICE
Dimensions, Weight, Power requirements
Powe 110/220 V, 50/60 Hz; 120 VA
Dimensions 600x480x220 mm
Weight 20 kg



RA-915AMNG

Specific References

Download

Brochure RA-915AMNG

Lumex Instruments_RA-915AMNG_Mercury Analyzer for Natural Gas

Download (521.22KB)